Con 700

Conductivity / TDS / Temperature

Featuring auto-standardization, auto-calibration and auto-ranging capabilities, the Eutech CON 2700 accepts 2-cell and 4-cell electrodes, allowing a broad range of measurement at up to ±1 % full scale accuracy. Meter comes with a multi data screen that shows Conductivity readings, temperature, electrode status, calibration points, date and time all at once.

• Choose auto-calibration with preset values for quick easy calibration, or manual multi-point calibration for greater accuracy
• Easy standardization with auto-standardization feature – detect the exact cell constant value of your electrodes with the press of a button
• Quick, easy electrode diagnosis with the effective cell constants display
• Replatinization in 5 minutes with the built-in replanitization circuit
• Non-volatile memory holds up to 500 data points – time and date-stamped for GLP compliance
• Bi-directional RS232 for easy data transfer to computer
• Cal-due alarm – no more out-dated calibrations!
• Auto-logging function for convenient continuous monitoring
• Limit alarm alerts when reading falls out of range
• Password protection for setup and calibration 
 

Applications

• Environmental studies • Chemical laboratories • Quality assurance testing
• Food science • Ecological studies • Education institution

 

 

Product Specification Description
Conductivity  
Range 0.050 µS to 500.0 mS
Resolution 0.01 / 0.1 µS ; 0.001 / 0.01 / 0.1 mS
 
Accuracy ±1 % full scale
Cal. Points Up to 5
Cell Constant 0.010 to 10.000
TDS  
Range (Depending
On TDS Factor)
0.050 ppm to 500 ppt
(@ TDS factor 1.00)
Resolution 0.01 / 0.1 ppm ; 0.001 / 0.01 / 0.1 ppt
 
Accuracy ±1 % full scale
Cal. Points Up to 5
Salinity  
Range 0.0 to 80.0 ppt
Resolution 0.01 / 0.1 ppm ; 0.001 / 0.01 / 0.1 ppt
Accuracy ±1 % full scale
Resistivity  
Range 2.000 Ohm to 20.0 MOhm
Resolution 0.01 / 0.1 Ohm ; 0.001 / 0.1 kOhm ; 0.01 MOhm
Accuracy ±1 % full scale
Temperature  
Range (Meter) 0.0 to 100.0 ºC / 32.0 to 212.0 ºF
Resolution 0.1 ºC / 0.1 ºF
Accuracy ±0.3 ºC / ±0.5 ºF
Coefficient (Per ºC) Linear & pure ; 0.000 to 10.000 %
Normalization 15.0 to 30.0 ºC / 59.0 to 86.0 ºF
Compensation ATC / MTC
Power Requirements 9 V DC adapter, 1.3 A (100/240 VAC, SMPS)

 